Fuji CAC Joint Stock CompanyInnovating Energy Technology
Fuji CAC · Engineering & Construction

Cleanroom Design & Construction in Vietnam

Fuji CAC brings cleanrooms, HVAC, electrical systems and process utilities into one coordinated facility package for semiconductor, electronics and advanced manufacturing projects in Vietnam.

A cleanroom connected to the whole facility

New facilities, rented-factory conversions, expansions and cleanroom renovations each need a defined design basis. Delivery may be an integrated Design & Build / general contractor package or a specialist scope, with responsibilities agreed for each project.

CSA & cleanroom fit-out

Civil, structural and architectural interfaces; cleanroom partitions, ceilings, finishes and coordinated people and material flows.

HVAC & process utilities

Air handling, filtration, pressure relationships and utility distribution; process gases, DI water and equipment connections within the agreed scope.

Electrical & facility controls

Power distribution, ELV, BMS/FMCS interfaces and monitoring, coordinated with installation, testing and commissioning.

Cleanroom design workflow

Cleanroom design workflow — an engineering concept, not a completed-project photograph.
Cleanroom design workflow — an engineering concept, not a completed-project photograph. Open full-resolution illustration ↗
Read the nine design stages
  1. Product and process

    Identify process steps, tool requirements and product-quality targets.

  2. Contamination risks

    Assess particles, AMC, ESD, heat, moisture and vibration as relevant.

  3. User requirements

    Define zones, people and material flows, utilities and safety.

  4. Cleanliness criteria

    Specify ISO class, particle sizes and occupancy state for each zone.

  5. Design basis

    Agree loads, airflow strategy, pressure relationships and resilience.

  6. Detailed criteria

    Set process-specific limits for environmental conditions and utilities.

  7. Integrated design

    Coordinate architecture, HVAC, filtration, tool exhaust and controls.

  8. Verification

    Commission, classify air cleanliness and test agreed performance.

  9. Operation

    Handover records, train operators and implement monitoring and maintenance.

Cleanroom air systems

A common configuration for semiconductor and electronics cleanrooms combines a make-up air unit (MAU), fan filter units (FFUs) and dry cooling coils (DCCs). Air returns through a perforated raised floor and the underfloor plenum, completing a controlled recirculation loop.

MAU + FFU + DCC with raised-floor return. The final configuration is tailored to process and safety requirements.

MAU make-up air joins the ceiling plenum. FFUs circulate air through the room, raised-floor return and DCC; process exhaust leaves separately.

Illustrative airflow · Animation speeds do not represent design velocities.

MAU + FFU + DCC with raised-floor return. The final configuration is tailored to process and safety requirements. Open full-resolution illustration ↗

How the air moves

  1. MAU · Condition outdoor air

    The MAU filters and conditions outdoor air, including cooling and dehumidification. Make-up air is balanced against exhaust and room leakage; reheat or humidification is added when required.

  2. FFU · Supply filtered air

    Ceiling-mounted fan filter units draw air from the supply plenum and deliver it to the room through HEPA or ULPA filters selected for the process.

  3. Raised floor · Collect return air

    Air passes down through perforated floor panels into the underfloor return plenum, then rises through the side return shafts.

  4. DCC · Remove sensible heat

    Dry cooling coils cool the return air before it re-enters the ceiling plenum. Coil surfaces stay above the local air dew point to avoid condensation; the FFUs circulate the air again.

Engineering decisions that depend on your process

Process-specific cleanliness

Wafer fabrication, assembly, packaging and test do not share one universal cleanroom class. Assess room-level and tool-level protection separately. A mini-environment can provide local protection where justified by the process.

Environmental and ESD controls

Specify temperature, relative humidity, pressure relationships, vibration and process lighting from tool and product requirements. Establish an ESD control programme where applicable; humidity control alone does not demonstrate ESD protection. ISO particle class does not prescribe a universal ACH, pressure difference, room velocity or filter coverage.

Molecular contamination and safety

Assess AMC separately where chemicals threaten the product or process. HEPA/ULPA particulate filters do not, by themselves, demonstrate control of gas-phase molecular contaminants. Hazardous tool exhaust requires dedicated containment and compatible exhaust/treatment arrangements. Room pressure must satisfy both contamination control and safety; positive pressure is not appropriate for every space.

Verification and continued operation

Agree commissioning and acceptance tests before design freeze. Depending on scope, these can include particle classification, installed-filter leakage, airflow, pressure, temperature/humidity, airflow visualisation, recovery and safety interlocks. Monitoring follows an agreed risk-based plan. IQ/OQ/PQ may be used under the client’s qualification framework; it is not a universal semiconductor handover requirement.

Design concepts

Explore an ISO Class 5 cleanroom

See how people, materials and controlled air move through a cleanroom—from the room layout to the temperature concept.

Separate routes. A coordinated clean zone.

ISO Class 5 layout concept showing gowning and personnel entry, a separate material-preparation and transfer route, the process room, and a controlled exit route.

Personnel

Gowning → controlled personnel entry → process room

Materials

Preparation → material airlock or pass-through → process room

Exit & waste

De-gowning and controlled removal routes, coordinated with operations

Illustrative zoning: room grades, air showers, airlocks and pressure relationships are selected for the process. “Class 100” is an approximate legacy comparison to ISO Class 5 at ≥0.5 µm.

Follow the air—and the heat

A 22-second concept animation follows MAU supply, FFU downflow, equipment heat, raised-floor return and DCC cooling.

22 seconds · Silent · English on-screen labels

The displayed temperatures and room dimensions are example assumptions. This concept animation is not a validated CFD study or evidence of ISO Class 5 performance.

Read the animation sequence
  1. The MAU supplies conditioned outdoor air to the ceiling plenum.
  2. FFUs filter the air and direct it down into the clean zone.
  3. Process equipment adds heat to the room air.
  4. Warmer air returns through the raised floor.
  5. The DCC removes sensible heat before the air returns to the ceiling plenum.
  6. Process exhaust follows a separate discharge path.

Layout & circulation

Scroll sideways to inspect the room layout on smaller screens.

ISO Class 5 layout concept showing gowning and personnel entry, a separate material-preparation and transfer route, the process room, and a controlled exit route.

Illustrative zoning: room grades, air showers, airlocks and pressure relationships are selected for the process. “Class 100” is an approximate legacy comparison to ISO Class 5 at ≥0.5 µm.

Cleanroom particle classification

Comparison at the cumulative particle-size threshold ≥0.5 µm
ISO 14644-1ISO limit particles/m³ at ≥0.5 µmLegacy FS 209E English class
ISO 335≈ Class 1
ISO 4352≈ Class 10
ISO 53 520≈ Class 100
ISO 635 200≈ Class 1 000
ISO 7352 000≈ Class 10 000
ISO 83 520 000≈ Class 100 000

FS 209E was withdrawn on 29 November 2001. Its English class numbers use a particles/ft³ basis. This is an approximate crosswalk at ≥0.5 µm, not an interchangeable full classification or test method. Specify the zone, ISO class, particle size(s), occupancy state and agreed verification criteria.

Relevant experience, with a defined scope

Semiconductor facility upgrade & expansion

Design & Build of electrical infrastructure, utility distribution and CSA works, including cleanroom renovation and facility upgrades.

Read the scope of work

Warehouse/RBF-to-advanced factory conversion

Design & Build of CSA, cleanrooms, electrical systems, HVAC, process gases, DI water and fire protection for a semiconductor facility.

Read the scope of work

Advanced manufacturing facility

General contracting for coordinated building fit-out, MEPF and process utilities, including installation, testing, commissioning and handover.

Read the scope of work

Questions before planning a cleanroom

Is ISO Class 6 the same as Class 100?

No. At the cumulative particle-size threshold ≥0.5 µm, ISO Class 5 is approximately comparable to legacy FS 209E Class 100, and ISO Class 6 to Class 1,000. The comparison does not replace full classification or the agreed testing method.

Does every semiconductor or electronics process need the same cleanroom?

No. Define the product, process steps, equipment and contamination risks first. The ISO particle class, occupancy state, environmental controls and utility requirements are then specified for each zone.

Can a rented factory or warehouse be converted?

Fuji CAC’s documented experience includes conversion of existing warehouses into manufacturing facilities. Feasibility depends on the building condition, available utilities, layout, process requirements and agreed scope.

What information should we send for an initial discussion?

Send the project location, available drawings, production process, cleanroom area, target class and occupancy state if known, equipment utility requirements, expected delivery scope and target schedule.

Planning a cleanroom or electronics facility in Vietnam?

Share your location, floor plan, production requirements and target schedule. Our team can discuss the facility scope, engineering interfaces and next information needed.

Technical references

General technical guidance. The project design basis, applicable standards and acceptance criteria are agreed for each facility.